RKI Instruments INC


- RKI Instruments GX-3R Confined Space 4 Gas Personal Gas Detector 72-RA-CIn-Stock Ships Quickly According to Your Carrier SelectionSKU: RKI-72-RA-C$54400
- RKI Instruments Calibration Kit for GX-3R & GX-3R Pro 81-GX3RHSCO-LVSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-GX3RHSCO-LV$39000
- RKI Instruments Calibration Station for the GX-3R & GX-3R Pro 81-SDM3R102Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-SDM3R102$1,65500
- RKI Instruments GasWatch 3 w/ Dual CO/O2 Sensor, Watch Band 73-0026-01Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-73-0026-01$48749
- RKI Instruments 34AL 4 Gas Mixture Calibration Aluminum Cylinder 81-0154RK-04Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-0154RK-04$16800
- RKI Instruments GasWatch 3 w/ Dual CO/O2 Sensor, Alligator Clip 73-0026Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-73-0026$48749
- RKI Instruments GX-3R Pro Confined Space 5 Gas Personal Gas Detector W/ Bluetooth Wireless Communication Kit 72-PAX-C-56Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-72-PAX-C-56$1,47899
- RKI Instruments 34 Liter Aluminum Cylinder 81-0143RK-04Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-0143RK-04$24200
- RKI Instruments GX-3R Confined Space 4 Gas Personal Gas Detector Kit 72-RA-C-56On Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-72-RA-C-56$1,06349
- RKI Instruments Calibration Kit for GX-2003 & GX-2012 81-GX03HSCO-DLVSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-GX03HSCO-DLV$50000
- RKI Instruments Calibration Kit For GX-6000 34AL cyl 100ppm of Isobutylene/H2S/CO/CH4/O2 81-6ABX-DLVSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-6ABX-DLV$62000
- RKI Instruments Calibration Kit For GX-6000 34AL cyl CH4/O2/H2S/CO 81-6AXX-DLVSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-6AXX-DLV$54500
- RKI Instruments Calibration Station with Demand Flow Regulator 81-SDM3R202Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-SDM3R202$2,51459
- RKI Instruments GasWatch 3 w/ CO(-H2) Sensor, Watch Band 73-0025-01Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-73-0025-01$48749
- RKI Instruments GasWatch 3 w/ H2S Sensor, Alligator Clip 73-0022Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-73-0022$19219
- RKI Instruments GX-6000 for LEL / O2 / H2S / CO / VOC's (0 - 6;000 ppm PID) w/ Li-Ion battery pack & 115 VAC charger 72-6ABX-CSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-72-6ABX-C$3,02309
- RKI Instruments Inc ESR-X13P-OXY Replacement O2 Sensor for GX-3R & GX3R Pro ESR-X13P-OXYSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-ESR-X13P-OXY$16000
- RKI Instruments Inc Quad Mix 4-Gas Calibration Cylinder 81-0154RK-02Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-0154RK-02$18749
- RKI Instruments Inc Stand Alone Calibration Station 81-SDM3R101Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-SDM3R101$1,36200
- RKI Instruments RP-3R Pump w/ 10' hose; 10 Probe & Tapered Red Nozzle For GX-3R 81-1198In-Stock Ships Quickly According to Your Carrier SelectionSKU: RKI-81-1198$44500
- RKI Instruments Single Stand Alone Calibration Station For GX-2012 Gas Detector 81-SDM2012-02Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-SDM2012-02$1,52000
- RKI Instruments GasWatch 3 w/ CO(-H2) Sensor, Alligator Clip 73-0025Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-73-0025$48749
- RKI Instruments GasWatch 3 w/ H2S Sensor, Wrist Band 73-0022-01Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-73-0022-01$19219
- RKI Instruments GasWatch 3 w/ O2 Sensor, Watch Band 72-0012-01Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-72-0012-01$19219
- RKI Instruments GX-3R Pro Confined Space 5 Gas Personal Gas Detector W/ Bluetooth Wireless Communication 72-PAX-CSpecial Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-72-PAX-C$96019
- RKI Instruments RP-3R Pro Pump w/ 10' Hose; 10 Probe & Tapered Red Nozzle For GX-3R Pro 81-1200Special Order Once All Item(s) Received - Shipping Will CommenceSKU: RKI-81-1200$44500
RKI Instruments Personal Gas Detectors, Multi-Gas Confined Space Monitors & Sensors
Identify hidden atmospheric threats, protect your crew in confined vaults, and monitor hazardous industrial vapors with the selection of genuine RKI Instruments personal gas detectors at Ohio Power Tool. Slicing corners with uncalibrated or consumer-grade air sniffers leads to missed toxic leaks, false alarms, and severe jobsite safety liabilities. We stock professional single-gas and multi-gas detection devices engineered with advanced micro-sensor tracking loops. Whether you are prepping a utility trench, testing a refinery tank layout, or clearing a wastewater vault, these rugged, wearable instruments keep your crew safe.
Single-Gas Personal Sniffers: Dedicated Tracking for Toxic Hazards
Keep your field technicians agile with low-profile, clip-on personal detection. RKI single-gas monitors—such as the 04 Series and GasWatch 3—are lightweight, ultra-compact, and calibrated to watch a single target compound. Optimized for specific trade risks, these pocket-sized units monitor standalone hazards like carbon monoxide (CO), hydrogen sulfide (H2S), oxygen depletion (O2), or sulfur dioxide (SO2). They are the premier choice for utility workers and tunnel excavators entering environments with known baseline risks.
Multi-Gas Confined Space Monitors: Complete 4-Gas and 5-Gas Tracking Matrixes
When entering complex, unpredictable atmospheric conditions like wastewater facilities or chemical storage vaults, monitoring one threat isn't enough. Flagship multi-gas units like the GX-3R and GX-3R Pro simultaneously track up to four or five gases across LEL combustibles, O2, H2S, and CO. As the world's smallest personal 4-gas monitors, they clip securely within a worker's breathing zone without pulling on clothing or obstructing tools, providing an unyielding wall of personal defense.
Advanced Micro-Sensor Resilience: Silicone Poisoning Resistance and Long Life Cycles
Avoid early sensor fouling and high maintenance overhead when tracking gases around complex industrial compounds. RKI equips their premium personal monitors with a new generation of micro-sensors. The catalytic combustion LEL sensors utilize an innovative dual-filament architecture: if the primary filament becomes compromised or poisoned by silicone vapors, the secondary tracking grid takes over seamlessly. Paired with lead-free electrochemical O2 sensors boasting up to a 5-year lifespan, your field uptime stays maximized.
Why Source RKI Instruments from Ohio Power Tool?
At Ohio Power Tool, we understand that gas calibration and atmospheric compliance are absolute priorities for your safety managers. We carry a comprehensive stock of genuine RKI Instruments gas detectors, portable remote sample drawing pumps, certified calibration gas cylinders, automated bump test stations, and replacement sensors. Sourcing through an authorized distributor ensures your instrumentation is 100% authentic and eligible for commercial contractor tiers. Shop online or visit our Columbus showroom today to outfit your fleet.
RKI Instruments FAQ
What is the difference between a diffusion gas monitor and a sample-draw monitor?
The difference comes down to how air physically reaches the tracking sensors:
- Diffusion Monitors (Passive): Rely on natural air currents and gas movement to drift across the face of the exposed sensors. These are compact, wearable units meant to track the immediate air inside a technician's personal breathing zone.
- Sample-Draw Monitors (Active): Utilize an internal motorized pump or a clip-on pump attachment (like the RP-3R) to actively pull air through a long hose and probe line. This is mandatory for testing deep vaults, sewers, or tanks safely from above ground before any crew member steps inside.
What gases are standard on a 4-gas monitor, and what do their alert thresholds watch for?
Standard 4-gas confined space configurations simultaneously track four critical atmospheric hazards:
- LEL (Lower Explosive Limit): Tracks flammable gases (like methane) from 0 to 100% of the minimum concentration required to ignite an explosion in air.
- O2 (Oxygen): Tracks oxygen levels, triggering alarms if concentrations deplete below 19.5% (asphyxiation risk) or enrich past 23.5% (extreme fire hazard).
- CO (Carbon Monoxide): Monitors this toxic, odorless combustion byproduct in parts per million (ppm).
- H2S (Hydrogen Sulfide): Watches for toxic sewer gas hazards common in wastewater and petrochemical environments.
What is the difference between a bump test and a full calibration on a gas detector?
Both maintenance checks are vital for jobsite compliance, but they serve different roles:
- Bump Test: A quick pre-shift field check. You briefly expose the sensors to a targeted concentration of test gas to verify that the sensors respond accurately and the audible/visual alarms trigger properly. It takes less than a minute and should be performed daily.
- Calibration: A formal adjustment process where the instrument is hooked to a certified gas cylinder to reset its internal measurement curves to an exact baseline accuracy standard. This is typically required every 30 to 90 days depending on company policy.
What does hydrogen (H2) compensation change about a carbon monoxide (CO) sensor's accuracy?
Standard electrochemical CO sensors can suffer from cross-sensitivity to hydrogen gas. In industrial environments like refineries, steel mills, or battery charging bays where hydrogen is present, a standard detector will misinterpret the hydrogen as carbon monoxide, flashing false high alarms that trigger unnecessary evacuations. Selecting an RKI monitor with an H2-compensated CO sensor eliminates this cross-talk, filtering out the hydrogen signal to deliver precise carbon monoxide measurements.
What is silicone poisoning on an LEL sensor, and how does RKI prevent it?
Silicone vapors from common shop lubricants, sealants, and cosmetics can coat the hot bead filament of a standard catalytic LEL sensor, creating a glassy barrier that permanently blocks flammable gases from reacting. This destroys the sensor's ability to detect explosive threats. RKI's newer generation GX-3R monitors utilize an innovative dual-filament LEL sensor layout. If the internal electronics sense that the primary filament has become poisoned or unresponsive, the secondary tracking filament takes over automatically to sustain field protection.
What is the function of the non-compliance indicator lights on a personal RKI monitor?
To help safety supervisors quickly police a large site, units like the GX-3R feature an automated Non-Compliance Indicator layout. The instrument automatically flashes its external LED lights every 30 seconds if it is overdue for its scheduled bump test, if formal calibration is due, or if a recent gas alarm event has occurred. The flashing indicators alert management immediately if a technician enters a hot zone with an unverified safety tool.
What are TWA and STEL alarms, and how do they differ from a standard high-gas alarm?
Standard alarms trigger instantly when a gas spike occurs, while toxic sensor channels incorporate two time-weighted alarms to monitor cumulative exposure risks:
- TWA (Time-Weighted Average): Tracks an employee's average exposure to a toxic gas over a full 8-hour work shift to prevent chronic poisoning.
- STEL (Short-Term Exposure Limit): Calculates a rolling 15-minute average exposure ceiling to protect personnel against acute, short-duration toxic surges.
Can I safely use an RKI personal monitor inside an explosive fuel tank enclosure?
Yes, provided you verify the safety markings before entry. RKI personal gas detectors are engineered and certified as Intrinsically Safe (bearing CSA, ATEX, and IECEx approvals). This specialized electrical engineering guarantees that the device's internal circuits, switches, and battery connections cannot generate an electrical arc or high thermal spark capable of igniting explosive fuel vapors or airborne gas tracking streams within a classified zone.
Where can I buy bulk calibration gas tanks, dock stations, and replacement micro-sensors?
As an authorized stocking distributor and commercial safety procurement partner, Ohio Power Tool carries a complete portfolio of atmospheric diagnostic gear. We maintain deep regional field stock across SDM-3R standalone calibration stations, 4-gas blended calibration cylinders (34L, 58L, and 116L sizes), replacement micro-sensors, clip-on sample pumps, and water-blocking filtration adapters to keep your utility tracking loops running at peak efficiency.



























