The GX-6000 is the only multi-gas instrument with an 11.7 PID sensor option. If there are other requirements like confined space safety; a second instrument would be required. The GX-6000 provides the flexibility to configure one instrument for multiple applications;This reduces the need to purchase separate instruments for specific applications.
FEATURES:
- 6 Operating modes.
- Smallest 6 gas sample draw.
- 2 Interchangeable smart sensor slots.
- 4 PID options: 10.6 (2 ranges) eV; 10.0 eV; and 11.7 eV lamps.
- PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list.
- Benzene specific version.
- PPM Leak Check mode.
- LEL sensor protection mode.
- Man-down alarm.
- Panic alarm: Auto display rotation.
- Peak-bar display.
- LED Light source.
- Internal sample pump.
- Light weight; small; rugged IP-67 design.
- Interchangeable battery packs (Li-ion / alkaline).
- Operates up to 14 hours on Li-ion battery pack; fully recharges in 3 hours; 8 hours operation with alkaline pack.
- Field replaceable sensors; batteries; filters and pump.
- Intrinsically safe ATEX / IECEx / cCSAus.
APPLICATIONS:
- Confined Space Entry.
- Hazmat Response Teams.
- Arson Investigation.
- Remediation Site.
- Perimeter Monitoring.
- Leak Detection.
- Landfill Monitoring.
- Winery Tank Entry.
SPECIFICATIONS:
Gases & Detectable Ranges | ||
---|---|---|
PID Sensors (Part 1) | ||
Gas | Measuring Range | Reading Increment |
10.6 Lamp (600 VOC’s) | 0 – 50;000 ppb | 1 ppb: (< 5000 ppb) / 10 ppb: (> 5;000 ppb) |
0 – 6;000 ppm | 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) | |
10.0 Lamp (Benzene Specific) | 0.1 – 50 ppm | 0.01 ppm (0 ~ 10 ppm) / 0.1 ppm (10 ~ 50 ppm) |
10.0 Lamp (300 VOC’s) | 0 – 100 ppm | 0.01 ppm (0 ~ 10 ppm) / 0.1 ppm (10 ~ 100 ppm) |
11.7 Lamp (High Voltage Lamp) | 0 – 1000 ppm | 0.1 ppm |
PID Sensors (Part 2) | ||
Gas | Alarm Set Points | Accuracy (which ever is greater) |
10.6 Lamp (600 VOC’s) | A1: 5;000 ppb | ± 10% of reading; ± 1 digit |
A2: 10;000 ppb | ||
A1: 400 ppm | ||
A2: 1;000 ppm | ||
10.0 Lamp (Benzene Specific ) | No Alarms | |
10.0 Lamp 300 VOC’s | A1: 5 ppm / A2: 10 ppm | |
11.7 Lamp (High Voltage Lamp) | A1: 400 ppm / A2: 1;000 ppm | |
Galvanic (Part 1) | ||
Gas | Measuring Range | Reading Increment |
Oxygen (O2) | 0 – 40.0% Vol. | 0.1% Vol. |
Galvanic (Part 2) | ||
Gas | Alarm Set Points | Accuracy (which ever is greater) |
Oxygen (O2) | A1: 19.5 Vol. | ± 0.5% O2 |
A2: 23.5 Vol. | ||
Electro Chemical (Part 1) | ||
Gas | Measuring Range | Reading Increment |
Carbon Monoxide (CO) | 0 – 500 ppm | 1 ppm |
Hydrogen Sulfide (H2S) | 0 – 100.0 ppm | 0.5 ppm |
Electro Chemical (Part 2) | ||
Gas | Alarm Set Points | Accuracy (which ever is greater) |
Carbon Monoxide (CO) | A1: 25 ppm | ± 5% of reading or ± 5 ppm |
A2: 50 ppm | ||
TWA 25 ppm | ||
STEL 200 ppm | ||
Hydrogen Sulfide (H2S) | A1: 5.0 ppm | ± 5% of reading or ± 2 ppm |
A2: 30.0 ppm | ||
TWA 1.0 ppm | ||
STEL 5.0 ppm | ||
Toxics (EC Sensors) (Part 1) | ||
Gas | Measuring Range | Reading Increment |
Ammonia (NH3) | 0 – 400.0 ppm | 0.5 ppm |
Chlorine (Cl2) | 0 – 10.00 ppm | 0.05 ppm |
Hydrogen Cyanide (HCN) | 0 – 15.0 ppm | 0.1 ppm |
Nitrogen Dioxide (NO2) | 0 – 20.00 ppm | 0.05 ppm |
Sulfur Dioxide (SO2) | 0 – 99.90 ppm | |
Toxics (EC Sensors) (Part 2) | ||
Gas | Alarm Set Points | Accuracy (which ever is greater) |
Ammonia (NH3) | A1: 25 ppm | ± 10% of reading or ± 5% of full scale |
A2: 50 ppm | ||
Chlorine (Cl2) | A1: 0.5 ppm | |
A2: 1.0 ppm | ||
Hydrogen Cyanide (HCN) | A1: 5 ppm | |
A2: 10 ppm | ||
Nitrogen Dioxide (NO2) | A1: 3 ppm | |
A2: 6 ppm | ||
Sulfur Dioxide (SO2) | A1: 2 ppm | |
A2: 5 ppm | ||
IR Sensors (Part 1) | ||
Gas | Measuring Range | Reading Increment |
Carbon Dioxide (CO2) | 0 – 10;000 ppm | 20 ppm |
0 – 10.00% Vol. | 0.02% | |
Methane (CH4) | 0 – 100% LEL 0 – 100% Vol. | 1% LEL/ 0.5% Vol |
Hydrocarbons | 0 – 100% LEL 0 – 30% Vol. | |
IR Sensors (Part 2) | ||
Gas | Alarm Set Points | Accuracy (which ever is greater) |
Carbon Dioxide (CO2) | A1: 5;000 ppm | ± 5% of reading or ± 2% of full scale |
TWA 5;000 ppm | ||
A1: 0.50% Vol | ||
A2: 3.00% Vol | ||
STEL 3.00% Vol | ||
TWA 0.50% Vol | ||
Methane (CH4) | A1: 10% LEL / A2: 50% LEL | |
Hydrocarbons | ||
Catalytic (Part 1) | ||
Gas | Measuring Range | Reading Increment |
Hydrocarbons (CH4; std) | 0 – 100% LEL | 1% LEL |
Catalytic (Part 2) | ||
Gas | Alarm Set Points | Accuracy (which ever is greater) |
Hydrocarbons (CH4; std) | A1: 10%LEL | ± 5% of reading or ± 2% LEL |
A2: 50%LEL | ||
Alarm Types | ||
Gas alarm | Man-down | Trouble |
Low and high adjustable | 1st – self reset 2nd – latching | Low flow Sensor connection Low battery Circuit error Calibration range |
General Specifications | ||
Sample Method | Sample draw pump; flow rate 0.45 LPM; 50 foot sample range | |
Display | Digital LCD; autobacklight; peak bar display; auto display rotation; and customize order of gases | |
Audible Alarm | 95 dB at 1 ft. | |
Languages | English; Spanish; French; German; Italian; Japanese; Korean; Portuguese; Russian | |
Continuous Operation | 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack) | |
Operating Temp. & Humidity | -4°F to 122°F (-20°C ~ +50?); 0- 95% RH non condensing | |
Dimensions | 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) | |
Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) | |
Safety Design / Approvals | Explosion proof: IECEx ; ATEX ; TIIS ; cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking | |
Warranty | Two years material (including sensors) and workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp) | |
Accessories | ||
Standard Accessories | • Rubber boot | • Belt clip | • Hand strap | • Tapper nozzle | • Probe with hydrophobic & dust filter 3’ teflon lined hose | • Benzene pre-filter tubes and holder (benzene versions) |
Optional Accessories | • SDM-6000 calibration station | • Bundles with instrument carrying case and accessories | • Flexible probes | • Up to 50 foot sample hoses | • Filter set | • IrDA cable |
OPT SKU | RKI-72-6AXX-C |
---|---|
MPN | 72-6AXX-C |
Product Type | Gas Detection |
Google Category | Business & Industrial > Work Safety Protective Gear > Gas Mask & Respirator Accessories |
Weight | 2.00 |