RKI Instruments GX-3R Pro Confined Space 5 Gas Personal Gas Detector W/ Bluetooth Wireless Communication Kit 72-PAX-C-56

$1,355.00
Special Order Allow extra time for shipping - Our Sales Team will follow up if shipment is anticipated to be longer than 3 - 5 days.
SKU
RKI-72-PAX-C-56

RKI Instruments

GX-3R Pro Confined Space 5 Gas Personal Gas Detector W/ Bluetooth Wireless Communication Kit 72-PAX-C-56

The GX-3R Pro is the world’s smallest 5-gas monitor weighing only 4.58 ounces and fits in the palm of your hand (2.9” W x 2.6” H x 1.06” D). It simultaneously monitors and displays 5 different gases.The GX-3R Pro utilizes Bluetooth communication to display direct gas readings from the instrument to a phone app; which is available free on either iOS or Android phones.

FEATURES:

  • Simultaneous detection of 5 gases: LEL; O2; H2S; CO; and other optional sensors; (H2 Compensated CO sensor available).
  • Simple 2-button operation.
  • Bluetooth communication with iOS & Android App.
  • Non-Compliance Indicator.
  • 3 user adjustable alarm levels.
  • Panic Alarm: Tap instrument twice.
  • Man Down Alarm.
  • Impact resistant body.
  • Large full dot; auto-backlit display with auto-rotation.
  • Stealth mode for law enforcement.
  • Field replaceable sensors & filters.
  • Water and dust resistant design; IP66/68.
  • 3 Year Warranty.

APPLICATIONS:

  • Personal monitoring.
  • Confined spaces.
  • Refineries/petrochemical.
  • Utilities.
  • Oil and Gas.
  • Water/Wastewater.
  • Fire Services.
  • Law Enforcement.
  • Construction.

INCLUDES:

  • (1) GX-3R Pro Confined Space 5 Gas Personal Gas Detector W/ Bluetooth Wireless Communication (72-PAX-C)
  • (1) 100-240 VAC Charger
  • (1) 34AL cylinder CH4/O2/H2S/CO
  • (1) 0.25 LPM regulator
  • (1) Tubing
  • (1) Screwdriver
  • (1) Carrying Case

SPECIFICATIONS:

Detectable Gases
Sensor Slot 1: Carbon Monoxide (CO) & Hydrogen sulfide (H2S) *Interchangeable* (Part 1)
GasDetection PrincipleMeasuring Range (Increments)
H2S / CODual EC0 ~ 2000 ppm (1 ppm
0 ~ 200.0 ppm (0.1 ppm)
H2S OnlyEC0 ~ 200.0 ppm (0.1 ppm)
CO H2 CompensatedEC0 ~ 2;000 ppm
Sensor Slot 1: Carbon Monoxide (CO) & Hydrogen sulfide (H2S) *Interchangeable* (Part 2)
GasAccuracy StatementPreset Alarms
H2S / CO± 5% of reading or ± 5 ppm COA1: 25 ppm¦ A2: 50 ppm A3:1200 ppm¦TWA: 25 ppm STEL: 200 ppm
± 5% of reading or ± 2 ppm H2SA1: 5 ppm¦ A2: 30 ppm A3: 100 ppm¦TWA: 1.0 ppm STEL: 5.0 ppm
H2S Only± 5% of reading or ± 2 ppm H2SA1: 5 ppm¦ A2: 30 ppm A3: 100 ppm¦TWA: 1.0 ppm STEL: 5.0 ppm
CO H2 Compensated± 5% of reading or ± 2 ppm COA1: 25 ppm¦ A2: 50 ppm A3: 1200 ppm¦TWA: 25 ppm STEL: 200 ppm
Sensor Slot 2: Combustibles (Methane as standard) (Part 1)
GasDetection PrincipleMeasuring Range (Increments)
CH4 / HCCatalytic0 ~ LEL (1% LEL)
Sensor Slot 2: Combustibles (Methane as standard) (Part 2)
GasAccuracy StatementPreset Alarms
CH4 / HC± 5% of reading or ± 2 % LEL1st: 10% LEL ¦ 2nd: 25% LEL 3rd: 50% LEL ¦ Over:100% LEL
Sensor Slot 3: Oxygen (O2) (Part 1)
GasDetection PrincipleMeasuring Range (Increments)
O2EC0 ~ 40.0% Vol. (0.10%)
Sensor Slot 3: Oxygen (O2) (Part 2)
GasAccuracy StatementPreset Alarms
O2± 0.5% O2 Low 1: 19.5%¦ Low 2: 18.0% High: 23.5%¦ Over: 40.0%
Sensor Slot 4: Toxics & CO2 *Interchangeable* (Part 1)
GasDetection PrincipleMeasuring Range (Increments)
SO2EC0 ~ 100.0 ppm (0.05 ppm)
CO2 %IR*0 ~ 10.0% Vol. (0.01%)
CO2 ppmIR*0 ~ 10;000 ppm (20 ppm)
Sensor Slot 4: Toxics & CO2 *Interchangeable* (Part 2)
GasAccuracy StatementPreset Alarms
SO2± 10% of reading or ± 5 % of full scaleA1: 2 ppm¦ A2: 5 ppm A3: 100 ppm¦ TWA: 0.25 ppm STEL: 0.25ppm
CO2 %± 5% of reading or ± 2 ppmA1: 0.50% Vol.¦ A2: 3.00% Vol. A3: 4.00% Vol.¦ TWA: 0.50% Vol. STEL: 3.00% Vol.
CO2 ppm± 5% of reading or ± 2 ppmA1: 5;000 ppm¦ A2: N/A TWA: N/A¦STEL: N/A
Alarm Types
Gas Alarm2 increasing alarms
STEL
TWA
Overscale alarm
O2 decreasing/increasing
Trouble AlarmSensor disconnection
Low battery
Circuit error
Calibration range error
Cal or bump due alarm
BothMan Down Alarm
Panic Alarm
Display of Alarm
Gas AlarmFlashing LED’s
Continuous buzzer (100 db @ 30cm)
Flashing gas value
Vibration
Trouble AlarmFlashing LED’s
Intermittent buzzer (95 db @ 30cm)
Display of error message
Common Specifications
Sampling MethodDiffusion sampling standard (hand aspirator or clip-on motorized pump optional)
DisplayFull dot LCD with Autobacklight and Autorotation
Operating Temp. & Humidity-20°C ~ +50°C [ -4°F ~ +122°F ] 10 to 90% RH; non-condensing (continuous environment)
-40°C ~ +60°C [ -40°F ~ +140°F ] 0 to 95% RH; non-condensing (temporary environment)
Response Time Within 30 seconds (T90)
Power Source
ConfigLi-ionAlkaline
4-gas + EC25 hours16 hours
4-gas + IR16 hours7 hours
Dimension & Weight 2.9” W x 2.6” H x 1.06” D (Approx. 73 W x 65 H x 26 D mm); 4.58oz (with rubber boot)
Case MaterialExplosion proof; dust and water resistant to IP-66/68 (2m;1h) approval. Drop height 23 ft.
Bluetooth CommunicationBLE: with iOS and Android phone app: RK Link
DataloggingLogs user ID; station ID; Calibration & Bump Test history; Alarm Events & Alarm Trends
Standard AccessoriesAlligator clip
Protective rubber boot
Charger
Calibration adapter
Optional AccessoriesPadded carrying case
RP-3R Attachable sampling Pump with 4” rubber nipple; 10’ hose and probe (up to 40’ hose available)
USB to IrDA downloading cable for datalogger
SDM-3R calibration station
Hand aspirator
Safety Design / Approvals ATEX; CSA
Warranty Three years material and workmanship including sensors
"
More Information
Shipping Weight 2.00